Ensurepass.com : Ensure you pass the IT Exams
2018 Aug Cisco Official New Released 642-035
100% Free Download! 100% Pass Guaranteed!
Troubleshooting Cisco Unified Computing
Question No: 41
A Cisco UCS admin is trying to integrate Cisco UCS Manager with Active Directory Authentication. After the configuration is done, the admin is still unable to log in using LDAP credentials. When running a debug on the Fabric Interconnect, this error is displayed:
ldap_build_roles_and_locales_from_attr: No attr for usr profile
Which step was missed in the configuration?
-
The LDAP provider was not configured correctly.
-
The proper RBAC role(s) were not assigned to the user.
-
Cisco UCS Manager 2.1 is required for LDAP integration.
-
The quot;Attributequot; field in Cisco UCS was left blank.
Answer: B
Question No: 42
Which piece of information does the FSM provide?
-
the current task and status
-
a collection of blade statistics
-
the last user to access the resource
-
a list of faults currently suppressed by the Cisco UCS Manager
Answer: A
Question No: 43
Refer to the exhibit.
Which tab would be the most useful for troubleshooting a blade discovery problem?
-
Faults
-
Events
-
FSM
-
Servers
Answer: C
Question No: 44
A customer calls in a trouble ticket complaining of unacceptable read I/O latency on a Cisco UCS C210 M2 server with an LSI MegaRAID 9260-8i with an 8-disk RAID-10 virtual disk. As you validate the RAID controller configuration, which of these configured items impacts read performance at the controller level?
-
all disks are 146GB 6 Gb SAS 15K RPM SFF
-
read ahead cache is enabled
-
BGI rate = 0
-
strip size = 256k
-
no hot spare
Answer: D
Question No: 45
A Cisco UCS chassis has two ports on I/O Module 1 connected to Fabric Interconnect A, and two ports on I/O Module 2 connected to Fabric Interconnect B. The I/O modules are connected to ports 1 and 2 on their respective fabric interconnects, and end host mode is configured. After a link failure occurs on port 1 of I/O Module 1, what happens to the traffic that was pinned to that link?
-
The traffic fails until the link issue is resolved.
-
The traffic is repinned to I/O Module 2 link 1, which is connected to Fabric Interconnect B.
-
The traffic is repinned to the remaining link between I/O Module 1 and Fabric Interconnect A.
-
The traffic is repinned automatically to Fabric Interconnect B.
Answer: C
Question No: 46
Which CLI command identifies the service profile that is associated with a particular compute blade, VIF, vNIC type, link state, and pinned interface?
-
show service-profile path server 1/2
-
show service-profile circuit server 1/2
-
show server-blade circuit server 1/2
-
show server-blade path server 1/2
Answer: B
Question No: 47
A customer would like to create an Ethernet traffic monitoring session on a Cisco UCS
server to troubleshoot network connectivity. The customer has entered the following commands via CLI:
UCS-A# scope eth-traffic-mon
UCS-A /eth-traffic-mon # scope fabric a
UCS-A /eth-traffic-mon/fabric # create eth-mon-session EthMonitor33
UCS-A /eth-traffic-mon/fabric/eth-mon-session* # create dest-interface 2 12
UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface* # set speed 20gbps UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface* # commit-buffer UCS-A /eth-traffic-mon/fabric/eth-mon-session/dest-interface #
Which outcome will this command sequence produce?
-
It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 2, port 12, will set the admin speed to 20 Gb/s, and will commit the transaction.
-
It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 2, port 33, will set the admin speed to 20 Gb/s, and will commit the transaction.
-
It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 33, port 12, will set the admin speed to 20 Gb/s, and will commit the transaction.
-
It will create an Ethernet traffic monitoring session to copy and forward traffic to the destination port at slot 2, port 12, will set the admin speed to 10 Gb/s, and will commit the transaction.
Answer: A
Question No: 48
Why is Virtual Fibre Channel interface 19 in err-disable state?
-
Missing transceiver
-
Virtual interface is not bound to a physical interface
-
The associated physical interface is down
-
VSAN to VLAN binding mis-configured
Answer: D
Question No: 49 HOTSPOT
Answer:
Question No: 50
You have an unresponsive blade server. You suspect that there is an issue with the current firmware. Which action do you take to reboot the server from the Cisco UCS Manager GUI?
-
Reset the server.
-
Reset CIMC.
-
Reset BMC.
-
Recover the corrupt BIOS.
Answer: B
100% Ensurepass Free Download!
–642-035 PDF
100% Ensurepass Free Guaranteed!
–642-035 Dumps
EnsurePass | ExamCollection | Testking | |
---|---|---|---|
Lowest Price Guarantee | Yes | No | No |
Up-to-Dated | Yes | No | No |
Real Questions | Yes | No | No |
Explanation | Yes | No | No |
PDF VCE | Yes | No | No |
Free VCE Simulator | Yes | No | No |
Instant Download | Yes | No | No |